Siemens 3RT5044-1AG20 коммутационное устройство

Siemens 3RT5044-1AG20
SIEMENS · SIRIUS 3RT5044

Contactor AC 110 V 50/60 HZ AC3 30 kW 400 V 3-pole, size S3 screw terminal

Технические характеристики 3RT5044-1AG20

Технические данные Siemens 3RT5044-1AG20
ПараметрЗначение
Siemens 3RT5044-1AG20Contactor AC 110 V 50/60 HZ AC3 30 kW 400 V 3-pole, size S3 screw terminal
Сведения об изделии
product brand nameSIRIUS
product designationPower contactor
product type designation3RT5
General technical data
size of contactorS3
product extension auxiliary switchYes
power loss [W] for rated value of the current
at AC in hot operating state per pole4.6 W
without load current share typical6.75 W
type of calculation of power loss current-dependentquadratic
insulation voltage rated value1 000 V
degree of pollution3
surge voltage resistance rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1690 V
shock resistance at rectangular impulse
at AC6.8 g / 5 ms, 4 g / 10 ms
shock resistance with sine pulse
at AC10.6 g / 5 ms, 6.2 g / 10 ms
mechanical service life (operating cycles)
of contactor typical10 000 000
of the contactor with added auxiliary switch block typical10 000 000
Substance Prohibitance (Date)03/01/2017
Net Weight1.71 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
during operation-25 ... +60 °C
during storage-55 ... +80 °C
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
operating voltage
at AC-3 rated value maximum1 000 V
at AC-3e rated value maximum1 000 V
operational current
at AC-1 up to 690 V
at ambient temperature 40 °C rated value100 A
at ambient temperature 60 °C rated value90 A
at AC-3
at 400 V rated value65 A
at 690 V rated value47 A
at AC-3e
at 400 V rated value65 A
at 690 V rated value47 A
at 1000 V rated value25 A
connectable conductor cross-section in main circuit at AC-1
at 60 °C minimum permissible35 mm²
at 40 °C minimum permissible35 mm²
operational current for approx. 200000 operating cycles at AC-4
at 400 V rated value28 A
at 690 V rated value20 A
operating power
at AC-1
at 230 V at 60 °C rated value34 kW
at 400 V at 60 °C rated value59 kW
at 690 V at 60 °C rated value102 kW
at AC-3
at 230 V rated value18.5 kW
at 400 V rated value30 kW
at 500 V rated value37 kW
at 690 V rated value45 kW
at AC-3e
at 230 V rated value18.5 kW
at 400 V rated value30 kW
at 500 V rated value37 kW
at 690 V rated value45 kW
at 1000 V rated value30 kW
operating power for approx. 200000 operating cycles at AC-4
at 400 V rated value15.1 kW
at 690 V rated value18.6 kW
no-load switching frequency
at AC5 000 1/h
operating frequency
at AC-1 maximum1 000 1/h
at AC-3 maximum1 000 1/h
at AC-3e maximum1 000 1/h
at AC-4 maximum300 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
control supply voltage at AC
at 50 Hz rated value110 V
at 60 Hz rated value110 V
operating range factor control supply voltage rated value of magnet coil at AC
at 50 Hz0.8 ... 1.1
at 60 Hz0.85 ... 1.1
apparent pick-up power of magnet coil at AC
at 50 Hz247 VA
at 60 Hz247 VA
inductive power factor with closing power of the coil
at 50 Hz0.62
at 60 Hz0.62
apparent holding power of magnet coil at AC
at 50 Hz25 VA
at 60 Hz25 VA
inductive power factor with the holding power of the coil
at 50 Hz0.27
at 60 Hz0.27
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact0
number of NO contacts for auxiliary contacts instantaneous contact0
operational current at AC-12 maximum10 A
operational current at AC-15
at 230 V rated value6 A
at 400 V rated value3 A
operational current at DC-12
at 110 V rated value3 A
at 220 V rated value1 A
operational current at DC-13
at 24 V rated value6 A
at 110 V rated value1 A
at 220 V rated value0.3 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value50 hp
Short-circuit protection
design of the fuse link
for short-circuit protection of the main circuit
with type of coordination 1 requiredfuse gL/gG: 250 A
with type of coordination 2 requiredfuse gL/gG: 125 A
for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm and 75 mm DIN rail
height146 mm
width70 mm
depth139 mm
Connections/ Terminals
type of electrical connection
for main current circuitscrew-type terminals
for auxiliary and control circuitscrew-type terminals
type of connectable conductor cross-sections for main contacts
solid or stranded2x (2.5 ... 16 mm²)
finely stranded with core end processing2x (2.5 ... 35 mm²)
finely stranded without core end processing2x (10 ... 35 mm²)
type of connectable conductor cross-sections
for auxiliary contacts
finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
Safety related data
product function mirror contact according to IEC 60947-4-1Yes
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Further information
last modified:4/4/2026
Date 4/8/2026Subject to change without notice © Copyright Siemens 2026

Разрешения и сертификаты

General Product Approval Maritime application other
other Environment

Техническая документация по 3RT5044-1AG20

← Все исполнения 3RT5044

Ваша корзина

Оформить заказ