SIEMENS · SIRIUS 3RT6016
Contactor AC 110 V 50/60 HZ AC3 4 kW 400 V AUX contacts: 1 NC 3-pole, size S00 screw terminal
Запросить цену в WhatsApp ↗
По запросу
Технические характеристики 3RT6016-1AF02
| Параметр | Значение |
|---|---|
![]() | Contactor AC 110 V 50/60 HZ AC3 4 kW 400 V AUX contacts: 1 NC 3-pole, size S00 screw terminal |
| Сведения об изделии | |
| product brand name | SIRIUS |
| product designation | Power contactor |
| product type designation | 3RT6 |
| General technical data | |
| size of contactor | S00 |
| product extension auxiliary switch | Yes |
| power loss [W] for rated value of the current | |
| at AC in hot operating state per pole | 0.7 W |
| without load current share typical | 1.05 W |
| type of calculation of power loss current-dependent | quadratic |
| insulation voltage rated value | 690 V |
| degree of pollution | 3 |
| surge voltage resistance rated value | 6 kV |
| maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 | 400 V |
| shock resistance at rectangular impulse | |
| at AC | 6,7 g / 5 ms, 4,2 g / 10 ms |
| shock resistance with sine pulse | |
| at AC | 10,5 g / 5 ms, 6,6 g / 10 ms |
| mechanical service life (operating cycles) | |
| of contactor typical | 30 000 000 |
| of the contactor with added auxiliary switch block typical | 10 000 000 |
| Substance Prohibitance (Date) | 05/01/2012 |
| Net Weight | 0.22 kg |
| Ambient conditions | |
| installation altitude at height above sea level maximum | 2 000 m |
| ambient temperature | |
| during operation | -25 ... +60 °C |
| during storage | -55 ... +80 °C |
| Main circuit | |
| number of poles for main current circuit | 3 |
| number of NO contacts for main contacts | 3 |
| number of NC contacts for main contacts | 0 |
| operating voltage | |
| at AC-3 rated value maximum | 690 V |
| at AC-3e rated value maximum | 690 V |
| operational current | |
| at AC-1 up to 690 V | |
| at ambient temperature 40 °C rated value | 22 A |
| at ambient temperature 60 °C rated value | 20 A |
| at AC-3 | |
| at 400 V rated value | 9 A |
| at 690 V rated value | 6.7 A |
| at AC-3e | |
| at 400 V rated value | 9 A |
| at 690 V rated value | 6.7 A |
| connectable conductor cross-section in main circuit at AC-1 | |
| at 60 °C minimum permissible | 2.5 mm² |
| at 40 °C minimum permissible | 4 mm² |
| operational current for approx. 200000 operating cycles at AC-4 | |
| at 400 V rated value | 4.1 A |
| at 690 V rated value | 3.3 A |
| operating power | |
| at AC-1 | |
| at 230 V rated value | 7.5 kW |
| at 230 V at 60 °C rated value | 7.5 kW |
| at 400 V at 60 °C rated value | 13 kW |
| at 690 V at 60 °C rated value | 22 kW |
| at AC-3 | |
| at 230 V rated value | 2.2 kW |
| at 400 V rated value | 4 kW |
| at 690 V rated value | 5.5 kW |
| at AC-3e | |
| at 230 V rated value | 2.2 kW |
| at 400 V rated value | 4 kW |
| at 690 V rated value | 5.5 kW |
| operating power for approx. 200000 operating cycles at AC-4 | |
| at 400 V rated value | 2 kW |
| at 690 V rated value | 2.5 kW |
| no-load switching frequency | |
| at AC | 10 000 1/h |
| operating frequency | |
| at AC-1 maximum | 1 000 1/h |
| at AC-3 maximum | 750 1/h |
| at AC-3e maximum | 750 1/h |
| at AC-4 maximum | 250 1/h |
| Control circuit/ Control | |
| type of voltage of the control supply voltage | AC |
| control supply voltage at AC | |
| at 50 Hz rated value | 110 V |
| at 60 Hz rated value | 110 V |
| operating range factor control supply voltage rated value of magnet coil at AC | |
| at 50 Hz | 0.8 ... 1.1 |
| at 60 Hz | 0.85 ... 1.1 |
| apparent pick-up power of magnet coil at AC | |
| at 50 Hz | 27 VA |
| at 60 Hz | 31.7 VA |
| inductive power factor with closing power of the coil | |
| at 50 Hz | 0.8 |
| at 60 Hz | 0.81 |
| apparent holding power of magnet coil at AC | |
| at 50 Hz | 4.2 VA |
| at 60 Hz | 4.8 VA |
| inductive power factor with the holding power of the coil | |
| at 50 Hz | 0.25 |
| at 60 Hz | 0.25 |
| Auxiliary circuit | |
| number of NC contacts for auxiliary contacts instantaneous contact | 1 |
| number of NO contacts for auxiliary contacts instantaneous contact | 0 |
| operational current at AC-12 maximum | 10 A |
| operational current at AC-15 | |
| at 230 V rated value | 10 A |
| at 400 V rated value | 3 A |
| at 690 V rated value | 1 A |
| operational current at DC-12 | |
| at 24 V rated value | 6 A |
| at 110 V rated value | 3 A |
| at 220 V rated value | 1 A |
| operational current at DC-13 | |
| at 24 V rated value | 6 A |
| at 110 V rated value | 1 A |
| at 220 V rated value | 0.3 A |
| contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
| UL/CSA ratings | |
| yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value | 5 hp |
| Short-circuit protection | |
| design of the fuse link | |
| for short-circuit protection of the main circuit | |
| with type of coordination 1 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A |
| with type of coordination 2 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A |
| for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
| Installation/ mounting/ dimensions | |
| mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
| fastening method side-by-side mounting | Yes |
| fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022 |
| height | 57.5 mm |
| width | 45 mm |
| depth | 73 mm |
| required spacing | |
| with side-by-side mounting | |
| at the side | 0 mm |
| Connections/ Terminals | |
| type of electrical connection | |
| for main current circuit | screw-type terminals |
| for auxiliary and control circuit | screw-type terminals |
| type of connectable conductor cross-sections for main contacts | |
| solid or stranded | 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm² |
| finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| type of connectable conductor cross-sections | |
| for auxiliary contacts | |
| solid or stranded | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² |
| finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| for AWG cables for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14), 2x 12 |
| Safety related data | |
| product function mirror contact according to IEC 60947-4-1 | Yes |
| Electrical Safety | |
| protection class IP on the front according to IEC 60529 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
| Further information | |
| last modified: | 4/4/2026 |
| Date 4/8/2026 | Subject to change without notice © Copyright Siemens 2026 |
Разрешения и сертификаты
| General Product Approval | |||||
|
|
|
|
Confirmation |
|
|
| EMV | Maritime application | other | Environment | ||
|
|
CCS (China Classification Society) |
Confirmation |
|
Environmental Confirmations |
|
Изображения и чертежи 3RT6016-1AF02
Техническая документация по 3RT6016-1AF02
- SIRIUS_cat_Sim.pdfразмер: 13.48 Мб, страниц: 52
- Каталог продукции «Контакторы и контакторные сборки Sirius 3RT»язык: RU, размер: 13.23 Мб, страниц: 3
- Обзорный каталог «Пускорегулирующая аппаратура Siemens SIRIUS»язык: RU, размер: 666.39 Кб, страниц: 3
- Брошюра «Низковольтные коммутационные аппараты Sirius Innovations»язык: RU, размер: 5.74 Мб, страниц: 4
- Брошюра «Sirius Innovations для специальных применений. Решения для частых коммутаций или плавного запуска электродвигателей»язык: RU, размер: 254.45 Кб, страниц: 4
- Брошюра «Пускорегулирующая аппаратура Sirius: обзор основных позиций – 2020»язык: RU, размер: 3.66 Мб, страниц: 24