Siemens 3RT6026-1BB40
SIEMENS · SIRIUS 3RT6026

Contactor DC 24 V AC3 11 kW 400 V AUX contacts 1 NO +1 NC 3-pole, size S0 screw terminal

Технические характеристики 3RT6026-1BB40

Технические данные Siemens 3RT6026-1BB40
ПараметрЗначение
Siemens 3RT6026-1BB40Contactor DC 24 V AC3 11 kW 400 V AUX contacts 1 NO +1 NC 3-pole, size S0 screw terminal
Сведения об изделии
product brand nameSIRIUS
product designationPower contactor
product type designation3RT6
General technical data
size of contactorS0
product extension auxiliary switchYes
power loss [W] for rated value of the current
at AC in hot operating state per pole1.9 W
without load current share typical5.9 W
type of calculation of power loss current-dependentquadratic
insulation voltage rated value690 V
degree of pollution3
surge voltage resistance rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
shock resistance at rectangular impulse
at DC10g / 5 ms, 7,5g / 10 ms
shock resistance with sine pulse
at DC15 g / 5 ms, 10 g / 10 ms
mechanical service life (operating cycles)
of contactor typical10 000 000
of the contactor with added auxiliary switch block typical10 000 000
Substance Prohibitance (Date)05/01/2012
Net Weight0.58 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
during operation-25 ... +60 °C
during storage-55 ... +80 °C
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
operating voltage
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
operational current
at AC-1 up to 690 V
at ambient temperature 40 °C rated value40 A
at ambient temperature 60 °C rated value35 A
at AC-3
at 400 V rated value25 A
at 690 V rated value13 A
at AC-3e
at 400 V rated value25 A
at 690 V rated value13 A
connectable conductor cross-section in main circuit at AC-1
at 60 °C minimum permissible10 mm²
at 40 °C minimum permissible10 mm²
operational current for approx. 200000 operating cycles at AC-4
at 400 V rated value9 A
at 690 V rated value9 A
operating power
at AC-1
at 230 V rated value13.3 kW
at 230 V at 60 °C rated value13.3 kW
at 400 V at 60 °C rated value23 kW
at 690 V at 60 °C rated value40 kW
at AC-3
at 230 V rated value5.5 kW
at 400 V rated value11 kW
at 690 V rated value11 kW
at AC-3e
at 230 V rated value5.5 kW
at 400 V rated value11 kW
at 690 V rated value11 kW
operating power for approx. 200000 operating cycles at AC-4
at 400 V rated value4.4 kW
at 690 V rated value7.7 kW
no-load switching frequency
at AC5 000 1/h
at DC1 500 1/h
operating frequency
at AC-1 maximum1 000 1/h
at AC-3 maximum750 1/h
at AC-3e maximum750 1/h
at AC-4 maximum250 1/h
Control circuit/ Control
type of voltage of the control supply voltageDC
control supply voltage at DC rated value24 V
operating range factor control supply voltage rated value of magnet coil at DC
initial value0.8
full-scale value1.1
closing power of magnet coil at DC5.9 W
holding power of magnet coil at DC5.9 W
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact1
number of NO contacts for auxiliary contacts instantaneous contact1
operational current at AC-12 maximum10 A
operational current at AC-15
at 230 V rated value10 A
at 400 V rated value3 A
at 690 V rated value1 A
operational current at DC-12
at 24 V rated value6 A
at 110 V rated value3 A
at 220 V rated value1 A
operational current at DC-13
at 24 V rated value6 A
at 110 V rated value1 A
at 220 V rated value0.3 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value15 hp
Short-circuit protection
design of the fuse link
for short-circuit protection of the main circuit
with type of coordination 1 requiredgL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 100 A
with type of coordination 2 requiredgL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A
for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
height85 mm
width45 mm
depth107 mm
required spacing
with side-by-side mounting
at the side0 mm
Connections/ Terminals
type of electrical connection
for main current circuitscrew-type terminals
for auxiliary and control circuitscrew-type terminals
type of connectable conductor cross-sections for main contacts
solid or stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
type of connectable conductor cross-sections
for auxiliary contacts
solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
Safety related data
product function mirror contact according to IEC 60947-4-1Yes
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Further information
last modified:4/4/2026
Date 4/8/2026Subject to change without notice © Copyright Siemens 2026